SMA Sunny Boy SB3000 Grid Tie inverter

SMA Sunny Boy SB3000 Grid Tie inverter
 
Art.No.:PD-01199
Weight:32,00 kg
Manufacturer:SMA
Delivery time: Directly delivering

 
Including VAT (19%)
excl. Transport surcharge

 Piece Add to cart
SMA SUNNY BOY 3000 GRID TIE INVERTER
 

Safe

  • Integrated ESS DC switch-disconnector
  • Galvanic isolation


All purpose

  • For indoor and outdoor installation
  • Suitable for generator grounding


Reliable

  • Tried and tested technology
  • Maintenance free, thanks to convection cooling


Simple

  • DC plug system SUNCLIX
TECHNICAL DATA
 
Sunny Boy 1200 Sunny Boy 1700 Sunny Boy 2500 Sunny Boy 3000
Input (DC)        
Max. DC power (@ cos f = 1) 1320 W 1850 W 2700 W 3200 W
Max. DC voltage 400 V 400 V 600 V 600 V
MPP voltage range 100 V 320 V 147 V 320 V 224 V 480 V 268 V 480 V
DC nominal voltage 120 V 180 V 300 V 350 V
Min. DC voltage / start voltage 100 V / 120 V 139 V / 180 V 224 V / 300 V 268 V / 330 V
Max. input current / per string 12.6 A / 12.6 A 12.6 A / 12.6 A 12 A / 12 A 12 A / 12 A
Number of MPP trackers / strings per MPP tracker 1 / 2 1 / 2 1 / 3 1 / 3
         
Output (AC)        
AC nominal power (@ 230 V, 50 Hz) 1200 W 1550 W 2300 W 2750 W
Max. AC apparent power 1200 VA 1700 VA 2500 VA 3000 VA
Nominal AC voltage; range 220, 230, 240 V; 180 V 265 V 220, 230, 240 V; 180 V 265 V 220, 230, 240 V; 180 V 265 V 220, 230, 240 V; 180 V 265 V
AC grid frequency; range 50, 60 Hz; 4.5 Hz 50, 60 Hz; 4.5 Hz 50, 60 Hz; 4.5 Hz 50, 60 Hz; 4.5 Hz
Max. output current 6.1 A 8.6 A 12.5 A 15 A
Power factor (cos f) 1 1 1 1
Phase conductors / connection phases 1 / 1 1 / 1 1 / 1 1 / 1
         
Efficiency        
Max. efficiency / Euro-eta 92.1 % / 90.9 % 93.5 % / 91.8 % 94.1 % / 93.2 % 95.0 % / 93.6 %
         
Protection devices        
DC reverse-polarity protection yes yes yes yes
ESS switch-disconnector yes yes yes yes
AC short circuit protection yes yes yes yes
Ground fault monitoring yes yes yes yes
Grid monitoring (SMA Grid Guard) yes yes yes yes
Galvanically isolated / all-pole sensitive fault current monitoring unit yes / yes / yes / yes /
Protection class / overvoltage category I / III I / III I / III I / III
         
General data        
Dimensions (W / H / D) in mm 440 / 339 / 214 440 / 339 / 214 440 / 339 / 214 440 / 339 / 214
Weight 23 kg 25 kg 28 kg 32 kg
Operating temperature range 25 C +60 C 25 C +60 C 25 C +60 C 25 C +60 C
Noise emission (typical) = 41 dB(A) = 46 dB(A) = 33 dB(A) = 30 dB(A)
Internal consumption: (night) < 0.1 W < 0.1 W < 0.25 W < 0.25 W
Topology LF transformer LF transformer LF transformer LF transformer
Cooling concept Convection Convection Convection Convection
Electronics protection rating / connection area (as per IEC 60529) IP65 / IP65 IP65 / IP65 IP65 / IP65 IP65 / IP65
Climatic category (per IEC 60721-3-4) 4K4H 4K4H 4K4H 4K4H
         
Features        
DC connection: SUNCLIX yes yes yes yes
AC connection: screw terminal / plug connector / spring-type terminal / yes / / yes / / yes / / yes /
Display: text line / graphic yes / yes / yes / yes /
Interfaces: RS485 / Bluetooth opt. / opt. opt. / opt. opt. / opt. opt. / opt.
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt.
Certificates and permits (more available on request) CE, VDE 0126-1-1, DK 5940**, RD 1663 , G83/1-1, CER/06/190 (only SB 1700), PPC, AS4777, EN 50438***, C10/C11, PPDS, IEEE 929, UTE C 15-712-1* CE, VDE 0126-1-1, DK 5940**, RD 1663 , G83/1-1, CER/06/190 (only SB 1700), PPC, AS4777, EN 50438***, C10/C11, PPDS, IEEE 929, UTE C 15-712-1* CE, VDE 0126-1-1, DK 5940**, RD 1663 , G83/1-1, CER/06/190, PPC, AS4777, EN 50438***, C10/C11, PPDS, UTE C 15-712-1* CE, VDE 0126-1-1, DK 5940**, RD 1663 , G83/1-1, CER/06/190, PPC, AS4777, EN 50438***, C10/C11, PPDS
         
* by request
**Only applies to IT variants
*** Does not apply to all national deviations of EN 50438
       
Data at nominal conditions        
Type designation SB 1200 SB 1700 SB 2500 SB 3000